英语人>网络例句>风 相关的搜索结果
网络例句

与 风 相关的网络例句 [注:此内容来源于网络,仅供参考]

A large range of IRZ and intense fluctuating velocity area around the boundary of IRZ is measured and thought to be important to keep the excellent ignition and combustion characters of the new kind swirl burner. Together with temperature trace method, different structure and operation parameter of the burner are studied in this paper about their effects on turbulent and mixing characters of swirling jet. The structure variation includes different blade angle, use of central gear shape baffle, variable outer length and angle of lean primary air outlet, use of wedge outlet of lean primary air.

采用上述两种测量方法并结合热质比拟温度示踪的方法,本文对径向浓淡旋流煤粉燃烧器喷口结构和气流流动参数的变化对旋流流场的流动、混合、湍流脉动特性的影响进行了深入研究,研究了旋流叶片倾角大小、中心齿型扩锥、淡一次扩口外伸长度和扩角的变化、淡一次楔形扩口、直流二次扩口角度的变化对出口旋转射流流动特性的影响,研究了一次率和旋流二次率运行参数变化的影响规律。

On the basis of the each principle of the method of anemography of balloon contrail and aeolian contour line radar,it analyzes and discusses emphatically on the differences between them as well as advantage and meaning of the method of anemography of aeolian contour line radar .

文章在介绍了气球轨迹法测廓线雷达测各自原理的基础上,重点分析、探讨了二者间的差异,以及采用廓线雷达测的优势与发展廓线雷达的意义。

Some parameters such as Indoor radiation heat transfer, convective heat transfer, MRT, OT, radiation heat transfer coefficient, convective heat transfer coefficient, and PMV-PPD were calculated under a steady condition. From the result, we can conclude, when operation under the combination system and worst-case test, if floor temperature is about 21℃, supply air temperature is 21℃, air velocity is 1m/s, the equlvalent coefficient of heat transfer between floor temperature and OT is 13.6w/m2k, where 5.68w/m2k is equlvalent coefficient of radiant heat transfer, 9.48w/m2k is convective heat transfer coefficient. And when air velocity is higher, supply air temperature is lower, the radiant heat transfer between floor and others is lower. In the whole experiment, the floor temperature was keeping above the indoor air dew point, and condensation was not appeared.

通过分析计算,在复合式系统运行中,最不利室外环境下,当地面温度维持在21℃左右,送温度21℃,送速1m/s,此时地板对作用温度的当量综合换热系数为13.6w/m2k,其中当量辐射换热系数为5.68w/m2k,对流换热系数为9.48w/m2k,并且送速度越高、送温度越低,地板与其他壁面的辐射换热量有一定程度的降低,但总供冷量增加;在整个实验中地板温度始终高于地板上层空气的露点温度,并未发现有结露现象;室内空气温度梯度能满足0.1m-1.1m的温差小于3℃的要求,并且适当提高送温度可以进一步提高人体的热舒适性。

Full automatic inductive wind drenchs corridor wind drenchs passageway or call wind to drench corridor: Use wind to drench machine achieve wind to drench depurative effect, main application divides the human body that enters clean workshop and the dirt that carry article surface to adhere to, bacterium to take a workshop at blowing, also have the effect of air strike at the same time, can prevent enter clean area without depurative air.

全自行感觉淋长廊淋路线或者叫淋长廊:使用淋机达到和实现淋过滤的作用,重要运用于吹除步入诘白工间的人,体和随带物件外面黏着的尘士、病菌带入工间,同时同样起着气伐的作用以及影晌,能够诅档没经过滤的空气air步入诘白地域。

Fifth, the wind pipe used to produce galvanized sheet, according to the length of the specific plant design size, the length of a single standard is not up to more than 6 meters, more than the other part of the total; room spray outdoor air supply system independent * 2 sets, UV room independent outdoor air supply * 1 set of systems, electrostatic dust removal chamber independent outdoor air supply system * 2 sets of independent outdoor air supply system include three filters.

五、管采用镀锌板制作,具体长度按厂房尺寸设计,标配长度单个最长不超过6米,超过部分另计;喷房室外独立送系统*2套,UV室室外独立送系统*1套,静电除尘室室外独立送系统*2套,独立室外送系统均包含三级过滤。

According to air door of flameproof fan work situation and its structure,a 3-D calculated model of air door is established with finite element analysis.

采用有限元分析方法,根据防爆门的工作情况和结构,建立了门的三维计算模型,运用ANSYS软件,对门的结构进行计算,具体包括门在载荷作用下所受的应力、产生的变形等,为优化门结构提供理论依据。

Ge Yusheng, General Secretary with Chinese As sociation of Light Industry Machinery seriously mentioned that Baodao-B-3 low-noise, strong-suction V suction-ironing table is unique in its kind, which successfully overcame the ins ufficient suction of old ironing table with its suction wind strength up to 350 Pa, whose whole stroke of suction valve adopts stamping by machinery mould, leaving smooth suction door of good sealing and low-noise etc. My personal involvement in this quality inspection witnessed the proven quality of Baodao brand.

中国轻工机械协会秘书长,高级工程师葛余生认真地讲宝岛牌YTT-B-3型低噪音强吸,V型吸烫台与同行业生产的不一样,很具有特色,解决了过去老式烫台吸不足的弊病,吸压强最高达350Pa,吸阀门全程采用机械模具冲制,使门光洁畅顺及密封性好,噪音低等特点(我亲自参加了这次质量检测,宝岛品牌名副其实),宝岛品质国内一流,与国际同步,替代进口,价格从优。

In this paper, the stationary and non-stationary random wind-induced response, dynamic reliability and optimization under the dynamic reliability constraint of structures with foundation rotation and tall building with TMD or TLD is studied systematically. Three achievements are gained. 1. According to the situation that Davenport wind spectrum is irrational fraction, the equivalent wind spectrum is generated by linear filtered process.

本文对基础转动结构、带TMD或TLD结构的高层建筑和高耸结构的平稳与非平稳随机振响应、动力可靠性分析以及基于动力可靠性约束的优化设计方法进行了系统的研究,取得了以下成果:1、针对Davenport脉动谱为非有理分式谱,通过线性滤波过程和三参数拟合,生成了与Davenport谱等效的脉动谱。

1 Oven order 5.1.1 first hearth cloth Wind board laying 200mm thickness of the bed material; About Revert cloth laying Wind board thickness 200mm bed material, to prevent Ogive burn plug secondary air pipe; 5.1.2 prior to Add a small amount of flammable wood furnace and left and right back Feeder, ignition Wind Road in oven two days before ignition; 5.1.3 ignition started Ovens need to use a small amount of diesel added to the accumulation of wood, wood ignition when combustible, wood drying to around 200 ° C, according to adjust primer wind baffle and then curves of thermal insulation and heating.

5.1烘炉顺序 5.1.1先将炉床布板上铺设厚度为200mm的床料;左右返料器布板上铺设厚度200mm床料,防止把帽烧坏,堵塞二次管; 5.1.2事先将少量易燃木柴放入炉膛和左、右返料器,点火道应在烘炉前2天进行点火; 5.1.3开始烘炉点火时需要用少量的柴油加在堆积的木柴上,点火时木柴易燃烧,木柴烘至200℃左右后,根据情况调节引挡板,再按升温曲线保温、升温。

The project area has three shopping malls in a row not to fight the fire area, with a total length of the circumference of more than 1 / 3, Road fire engines from the inside edge of the wing wall construction materials to highlight the edge of not less than 5.00m, and fire engines to meet the Road Fire The largest car turning radius of 12m, to fight the fire site with a width of 18m, and this is not tall tree planting; and fire fighting facilities of not more than 5% of the slope, fire engines, fire fighting facilities should be able to carry a large set of fire engines Weight; Combined air-conditioning unit: for department stores, supermarkets, large bays, such as the lobby room, a new unit set up wind, ventilation and air return, setting up a new, back to the wind and the proportion of exhaust valve, according to the outdoor temperature of the new regulation, the ratio of air return, Back to the water main unit based PI control valve and in accordance with return air-conditioning temperature valve opening.

本项目商场三个面设有不连续消防扑救面,总长度大于周长的1/3,消防车道内边路缘距建筑外墙突出物边缘不小于5.00m,且消防车道满足消防车最大12m 的转弯半径,消防扑救场地的宽度为18m,且此范围内没有种植高大乔木;此外消防扑救场地的坡度不大于5%,消防车道、消防扑救场地应能承载大型消防车的载重量;组合式空调机组:用于百货商场、超市、大厅等大开间房间,机组设新、回及排,设新、回及排比例调节阀,根据室外温度调节新、回比例,机组回水管设比例积分调节阀并根据回温度调节水阀开度。

第3/100页 首页 < 1 2 3 4 5 6 7 8 9 ... > 尾页
推荐网络例句

Means the parent directory, so this command means to execute "toolchain.sh," which is in the current directory.

代表父目录,所以这个命令就是执行当前目录下的"toolchain.sh"。

Yes,In fact,I'm on our city ream.

是的。事实上我是我们市队的。

The strong ionospheric disturbances caused by the significant magnetic storm appeared on the whole world.

用欧亚大陆地面电离层垂测站资料考察1989年3月12~16日磁暴期间的电离层暴形态及其发展变化。