Consideration of the structural characteristics of autotransformer, the principles and characteristics of zero-sequence differential protection are analyzed by taking PST1200 as an example, debugging method of zero-sequence differential protection is summed up briefly, the method can well verify the logical function correctness of zero-sequence differential protection, and it has been verified in practical application.

结合自耦变压器的结构特点,以南自PST1200变压器保护装置为例分析了零序差动的原理构成及特点,简要总结了零差保护的调试方法,能够较快且准确的校验零差保护逻辑功能的正确性,并已在实际工作中得到了很好的验证

This paper introduced an eigen-mode decomposing method to decouple zero sequence parameter in double circuit. The decomposing matrix of eigen-mode component is given. The zero sequence component relationship between voltages or currents at two terminals of double circuit was achieved by composing eigen-mode components.

提出一种采用特征模量分解方法对同杆多回线间的零序参数解耦,并给出了同杆双回线零序参数特征模量分解矩阵,通过特征模量分解得到同杆双回线路两端之间的零序电量关系。

Protection schemes based on the zero sequence fundamental voltage and the third harmonic voltage and the injection voltage are presented in this paper, and based on which, the factors which affects the protection schemes based on the zero sequence fundamental voltage and the relevant measures is presented.

本文在对基波零序电压型定子接地保护、三次谐波电压型定子接地保护和外加电源式定子接地保护各种方案的构成原理及其优缺点进行分析的基础上,详细分析了影响基波零序电压型定子接地保护的各种因素,并提出了相应措施。

Deduced by the ip iq detection method,it directly applied to asymmetric three phase four wire system,no need to remove zero sequence component,it is correctly detects the fundamental zero-sequence,negative sequence and harmonic component,the simulation results show that its conclusions are correct.

经推导,ip iq 检测法可直接应用于不对称三相四线制系统中,无需先剔除零序分量,同样能够正确检测出基波零序、负序及谐波分量,仿真结果证明其结论的正确性。

From the perspective of minimum transmission losses, an instantaneous reactive power theory for systems with any number of phases and with or without neutral line is developed. Under the new definition, each quantity has its own physical meaning, and the zero sequence current can be decomposed into active and reactive components. Furthermore, a generalized compensation method for zero sequence current is developed.

从输电损耗最小的角度出发,提出了任意相无中性线或有中性线系统的瞬时无功功率理论,在新的理论下,每个量都有清晰的物理意义,且能分解出零序电流的有功分量和无功分量,并给出了通用的零序电流补偿方法,揭示了瞬时无功功率理论与传统平均意义下的无功功率理论的联系及本质区别,从而为研究HVDC-VSC及各种FACTS装置的无功功率控制奠定了理论基础。

Protection The whole protection scheme for double-circuit lines on the same tower consists of split-phase current differential protection or split-phase composite distance carrier protection and zero-sequence directional comparison protection as main protection, and DPFC distance protection, step zones distance protection and zero-sequence directional over-current protection as backup protection.

2.2.1 。保护整个保护计划的双回线同杆包括分相电流差动保护或分相复合距离承运人的保护和零序方向比较保护为主要保护和DPFC距离保护,加强保护区的距离和零序方向过电流保护作为后备保护。

Grounded faults occur on transmission lines, may cause malfunction of currently available zero sequence directional element when zero sequence voltage can't meet the sensitive requirement.

输电线路发生接地故障时,可能因零序电压不满足灵敏度要求,而导致零序方向元件误动或者拒动。

Pilot zero sequence directional protection may fail to operate because the zero sequence current on one end does not reach the set value of the protective relay,although zero sequence directional elements on both ends operate correctly.

线路发生接地故障时,两侧零序阻抗相差过大将导致两侧零序电流差别过大,虽然两侧的零序方向元件均能正确动作,但是由于一侧零序电流达不到动作定值,从而造成纵联零序方向保护拒动。

The inverse time delay characteristic is adopted by the basic zero-sequence over-voltage protection. On the basis of the analysis of the transient negative current, a compensated voltage can be generated with multiplying the rms value of the negative sequence transient current of the feeder by a settable compensated reactance, then combined with the magnitude of the zero-sequence voltage to consist of the compounded compensated voltage, which can be utilized to revise the characteristics of the inverse time-delay.

其基本保护采用零序过电压保护,动作时间采用反时限特性;在分析接地故障负序暂态电流分布特点的基础上,利用线路负序电流暂态有效值与一个可整定的补偿电抗相乘,形成补偿电压,并与零序电压幅值合成复合补偿电压,利用该电压对基本的反时限动作特性曲线进行修正,使零序过电压保护具有选择性。

Based on symmetrical analysis theory, the stator current of motor is decompounded into positive-sequence current, negative sequence current and zero-sequence current to distinguish the running state and fault type of the motor according to their magnitude of current. The technology of INTEL80C196KB MCU is applied to design and fulfill a new kind of micro-processor protective device for asynchronous motor.

根据对称分量分析原理,将电动机定子电流分解成正序、负序和零序分量,依据各种序量的大小,判别电动机运行状态和各种故障类型;采用INTEL80C196KB单片机技术,实现了一种新型的异步电动机综合保护装置。

第1/8页 1 2 3 4 5 6 7 8 > 尾页
推荐网络例句

Cynanchum Lingtai apricot production in the average weight 65 grams, the brightly-colored fruit, juicy rich, sweet-sour taste, sweet from the nucleolus, when the late Qing Dynasty famous Shaanxi, Gansu provinces, the Qing imperial court Tongzhi tribute for years.

灵台生产的牛心杏平均单果重65克,果实色泽鲜艳,汁多味浓,甜酸适口,离核仁甜,清末时就驰名陕、甘两省,清同治年间曾为朝廷贡品。

Chenopodium album,Solanum nigrum, and Amaranthus retroflexus were very susceptible to the herbicides. Polygonum persicaria and Abutilon theophrasti were relatively less susceptible to the herbicides, and Lycopersicon esculentum was not susceptible to it. The relationship between reduction rates of weed biomass and PPM values of weed leaves 2,4, and 6 days after treatment was established.

供试的6种杂草对该混剂的敏感性存在显著差异:红心藜Chenopodium album、龙葵Solanum nigrum和反枝苋Amaranthus retroflexus对该混剂最敏感,ED90值分别为47.65、71.67和29.17g/hm2;春蓼Polygonum persicaria和苘麻Abutilon theophrasti敏感,ED90值分别为96.91、114.20g/hm2;而番茄不敏感。

However, I have an idea.

不过,我有个主意。