查询词典 residual errors
- 与 residual errors 相关的网络例句 [注:此内容来源于网络,仅供参考]
-
The law of factors' affecting degree, which influences the parameters between geogrids and soils in the pulling-out procedure, is obtained. With the concept of 'equivalent pull-out displacement' brought forward, the whole process of pull out tests is divided into two process-" main process (when x 1.0)" and "residual process (when x 1.0)", and three stages-static friction resistance stage, slip friction resistance stage, and residual friction resistance stage.2 The value of friction coefficient between reinforcement and soil varies with their definitions of friction, but each factor' s affecting degree influencing friction pa
将模糊控制理论引入了岩土工程过程分析,考虑影响因素影响程度的变化及其规律,提出了一套可供岩土工程过程分析中参数选择的分析方法,并在筋土界面相互作用参数选取的拉拔试验过程控制中获得实施,为应用有限元法对加筋土结构进行过程中南大学博士论文摘要分析提供了参数选择的新方法;将模糊聚类分析方法应用于加筋土陡边坡状态评定,并提出侧向位移可作为加筋土边坡状态评定的量化指标,而不同类型边坡的侧向位移允许控制值可仿效此法结合工程经验确定。
-
Due to higher content of residual deleterious elements in scrap, the arc furnace charging should contain iron/hot metal or DRI in definite proportion to decrease the content of residual deleterious elements in steel for oil well.
因废钢中残余有害元素含量较高,为降低油井用钢的残余元素含量,应在电弧炉炉料中加入一定比例的生铁或直接还原铁
-
This series of residual current circuit breaker is the residual current—operated electronic circuit breaker,composed of zero—sequence current transformer,electronic control leakage release and DZ20 type circuit breaker with overload and shod—circuit protection.
本系列断路器电流动作型电子式漏电断路器,主要由零序电流互感器、电子控制漏电脱扣器及带有过载和短路保护的DZ20型断路器组成。
-
The picrites have low Re and high Os concentrations, which are probably controlled by the degree of partial melting and crystallization fractionation. The low Re ,Yb and Re/Os ratios of the picritic lavas support models of high degree partial melting with residual garnet in their mantle source during the early stages of partial melting, and without residual sulphide.
木里地区苦橄岩具有低的Re含量和高的Os含量,Re和Os的含量受到熔融程度和结晶分异的控制,低的Re和Os的含量和Re/Os,以及高的Os含量支持高程度的地幔熔融导致熔体中的硫不饱和,同时源区可能有石榴子石残留。
-
It is shown that the ratio of relaxed value of residual stress to the original residual ...
研究表明,在高压聚乙烯反应管开停工的循环载荷和 34 0℃时的均匀温度场作用下,2 0年内管内壁自增强残余应力衰减量与初始残余应力值的比率在 5 3%以下。
-
The simulation results show that the distribution of longitudinal residual stress along the width of sheet is asymmetrical, and the residual distortion corresponds well with experimental results both in distortion pattern and deformation values on the whole sheet.
利用该模型可以得到不对称的纵向残余应力结果,残余变形的趋势在整块板上都与实验结果相同,而且变形量和实验测量值之间的误差在20%以内。
-
In this paper,the surface roughness and residual stress of 1Cr11Ni2W2MoV stainless steel after laser shock peening and shot peening were tested and analyzed.The results show that laser shock peening samples have better surface quality and larger residual stress than shot peening samples.
对不锈钢材料1Cr11Ni2W2MoV进行了激光冲击强化和喷丸强化后表面粗糙度和残余应力测试分析,与喷丸相比,激光冲击强化对试件表面形貌和表面粗糙度的影响更小,产生的残余压应力更大。
-
For the influence of the residual strain of alloyed plate on rolling force cannot be removed by conventional rolling force self-learn method,and based on the classic deformation resistance model,the influence of residual strain on rolling force is analyzed and correspondent mathematical model for engineering calculation is afford.
针对合金元素含量较多的中厚板在轧制过程中其残余应变对轧制力的影响无法通过自学习来克服的问题,在常规变形抗力模型的基础上,分析了残余应变对中厚板变形抗力的影响,并由此提出了残余应变的工程计算模型。
-
After the coagulation and sedimentation in the jar test with ferric chloride, the residual COD in the supernatant was 9000 mg/L which was further oxidized by chloric acid or with Fenton method. The COD removal efficient increased with the increasing of the dosage of chloric acid from 0.5 ~ 100 g/L or the H2O2/Fe2+ from 5/2.5 ~ 50/25 g/L, and the economical dosage were suggested as chloric acid 50 g/L or the H2O2/Fe2+ 50/25 g/L which resulted in the residual COD of 400 and 3300 mg/L individually for 95 and 63 % COD removal percentages. Oxidation test showed that only 5 minutes was needed for 92 % COD removal in the case of chloric acid dosage 50 g/L.
废液A经氯化铁混凝沉淀后,COD浓度可降低至9,000mg/L,仍未符合符合工业区污水厂进厂限值(<650mg/L),进而使用氯酸钠直接氧化法及Fenton法以去除剩余之COD,其操作条件范围分别为氯酸钠加药量0.5g ~ 100g/L ,而最适加药量为50g/L,及Fenton法H2O2/Fe2+加药量范围为5/2.5g/L~50/25g/L,其最适H2O2/Fe2+加药量为50/25g/L,两种方法处理后残余COD浓度分别为400mg/L及3300mg/L,去除率约为95%及63%,而依此判断氯酸钠氧化处理残余COD有较好之效果,且利用氯酸钠氧化速率快,5分钟就能有92%去除率,所需水力停留时间较短,由此实验建议利用氯酸钠直接氧化处理,最适加药量为50g/L。
-
Considering of present development tendency of the residual heat recovery technology in the coke industry, discuss the application conditions of the residual heat recovery and utilization in coke plant.
根据当前焦化行业的余热回收利用技术发展趋势,研究焦化厂余热回收利用工艺技术的应用情况和应用条件。
- 相关中文对照歌词
- Hymn For The Dead
- The Radio Is Broken
- Riffmaster B
- Doubt
- History
- Goliaths Disarm Their Davids
- Know How
- I Need You
- You Can't Stop Thinking About Me
- Hatin Nation
- 推荐网络例句
-
I can not negligent, he should do what?
我不能不在意了,他要做什么呢?
-
It is very dangerous to swim in the river alone.
一个人到河里游泳是很危险的。
-
Marlboro became one of the world's most valuable brands the old-fashioned way -- traditional mass marketing.
万宝路成为世界上最有价值的品牌走的是老式的道路――传统的大众市场。